Moderator: Mmiscool
ardhuru wrote:The IP defination in 'Settings' works (at least for SoftAP). BUT, I cant seem to make the ESP work as a station. The AP ssid keeps showing, one can also login into it, but there's no station visible (I can look for all devices connected to my router using an Android app called 'Fing'.
I am ABLE to connect to my local network and take either the DHCP address or set one in the settings for version 3.0. I haven't tried changing the IP address for the local AP yet.
This will not be added back as a command as it returns a value.
Any command that return returns a values is now gone and no more with this format will be created.
grzesiu wrote:Hi!
In function temp() (eval.ino) there is noCode: Select allso readed temperature is still 85*Csensors.requestTemperatures();
I propose that this function should be like this:Code: Select allelse if ( fname == F("temp") && num_args > 0 ) {
// function temp(sensor #)
// set return value
if(sensors.getAddress(tempDeviceAddress, args[0])) {
if( args[1] >= 9 && args[1] <= 12 ) { // optional argument to set resolution of DS18B20
sensors.setResolution(tempDeviceAddress, args[1]);
}
sensors.requestTemperatures();
*value = sensors.getTempC(tempDeviceAddress);
//sensors.getTempCByIndex(args[0]);
return PARSER_TRUE;
}
else
{
*value_str = "NO SENSOR";
return PARSER_STRING;
}
}
in commands.ino I propose to keep temp command but with small change.Code: Select allif ( Param0 == "temp" | Param0 == "ti")
{
valParam1 = GetMeThatVar(Param1).toInt();
// call sensors.requestTemperatures() to issue a global temperature
// request to all devices on the bus
sensors.requestTemperatures(); // Send the command to get temperatures
SetMeThatVar(Param2, String(sensors.getTempCByIndex(valParam1)), PARSER_STRING);
return;
}
or with resolution settings and sensor detection:Code: Select allif ( Param0 == "temp" | Param0 == "ti")
{
valParam1 = GetMeThatVar(Param1).toInt();
valParam3 = GetMeThatVar(Param3).toInt();
if(sensors.getAddress(tempDeviceAddress, valParam1)) {
if( valParam3 >= 9 && valParam3 <= 12 ) { //option resolution setting for DS18B20
sensors.setResolution(tempDeviceAddress, valParam3);
}
sensors.requestTemperatures();
SetMeThatVar(Param2, String(sensors.getTempC(tempDeviceAddress)), PARSER_STRING);
}
else
{
SetMeThatVar(Param2, String(F("NO SENSOR")), PARSER_STRING);
}
return;
}
keeping this readings in string is usable when You show temperature on LCD screen (still 2 digit afret comma)
Greetings: Grzesiu
http://esp8266basic.com
A BASIC interpreter for your ESP
Working now on Autodrop3d. A 3d printer with automatic part ejection system. https://autodrop3d.com